freiberufler LabVIEW Entwickler auf freelance.de

LabVIEW Entwickler

offline
  • 45€/Stunde
  • 83052 Bruckmühl, Mangfall
  • Europa
  • en  |  de
  • 01.02.2024

Kurzvorstellung

High Tech Instrumentation Engineer with work experience of LabVIEW & other third party
hardware and software for Industrial Automation & Data acquisition system for Automobile,
Defence ,Process, Research & development Industries.

Qualifikationen

  • LabView
  • NI Certified LabVIEW Developer;

Projekt‐ & Berufserfahrung

Application and Development Engineer (Festanstellung)
Kundenname anonymisiert, pune
8/2019 – 2/2023 (3 Jahre, 7 Monate)
Automobilindustrie
Tätigkeitszeitraum

8/2019 – 2/2023

Tätigkeitsbeschreibung

VCU Functional Test using NI TestStand, PXI and Third-Party Hardware’s

Project Description:
Designed and Developed Test Application for VCU Functional Test for 2 Stations. Test Sequences were written in TestStand 2014. And All Control Actions for Testing was Implemented through and In PLC. Software Implementation was done according to Brose Standard Codes & Architectures.

Eingesetzte Qualifikationen

LabView

Application and Development Engineer (Festanstellung)
Kundenname anonymisiert, Duesburg
4/2019 – 7/2019 (4 Monate)
Automobilindustrie
Tätigkeitszeitraum

4/2019 – 7/2019

Tätigkeitsbeschreibung

DN 15 Flow Meter Calibration using cRIO 9045

Project Description:
Designed and developed Application for Monitoring and Calibration of Flow meters. Common software was developed for 4 different Line Rigs. Communication between Host and RT done via Network Stream. Implementation of Two Hand Safety feature in the Software. NI Functional Safety Module 9350 was used to Control the Safety features (Operator’s safety) and Interlocks

Eingesetzte Qualifikationen

LabView

Application and Development Engineer (Festanstellung)
Kundenname anonymisiert, Köln
12/2018 – 3/2019 (4 Monate)
Automobilindustrie
Tätigkeitszeitraum

12/2018 – 3/2019

Tätigkeitsbeschreibung

High Voltage Test Rig using Schleich High Voltage Tester

Project Description:
Designed and developed Application for Monitoring and Testing Electronic Circuit Unit for Optiswirl Meters. Appropriate Voltage (Above 850 V) was provided to DUT to test its connections by steps. For each step corresponding relays were switched ON to provide Voltage to respective test points. Step results were interpreted by Current & Resistance values. Results saved in Local Database. Reports were generated for records. Two Hand Operation, Foot switch and Door closed safety features were too implemented

Eingesetzte Qualifikationen

LabView

Zertifikate

NI Certified LabVIEW Entwickler
Nationam Instrument
2018

Ausbildung

Instrumentation Engineering
Bachelor
2017
Maharashtra

Über mich

This high skilled LabVIEW Developer is employee of TMCS Group and specialized on LabVIEW Applications. His home base is India/ Pune with onsite presence on customer demand.
The work contract will be direct with TMCS via contact data given in this profile.

Weitere Kenntnisse

Software skills with LabVIEW and others
• Expert in industrial customized application development based on LabVIEW programming language
• Expert in developing modular and scalar code using different architectures
• Ability to understand critical LabVIEW Code and process systems in order to debugged or modify system coding
• System and code debugging proficiency
• Effective presentation and communication skills
• Excellent analytical skills
• Ability to work in a team environment and independently
• PLC programming and Integration with LabVIEW, Siemens, Mitsubishi
Hardware Interfaced with LabVIEW and others
• Various NI LabVIEW Toolkit: Sound & vibration, signal processing, NI FPGA, NI RT, NI Motion, Database and Report Generation
• Communication using different Protocol: EtherCAT , Ethernet, Modbus , CAN, GPIB, RS-232, RS-485, Ethernet, CAN Open, OPC, OPC UA
• PLC Interface with LabVIEW using Modbus, TCP and Ethernet Protocols.
• Types of PLC: Siemens S7-200, 300, Mitsubishi Motor Drives, Siemens Motor Drive, Fanuc Motor Drive by Mod bus Protocols, Roboteq Motor Drive Controlled, ECU communication by CAN open Protocol using NI CAN FPGA Module 9852/3, DC Voltage source Aplab

Persönliche Daten

Sprache
  • Englisch (Muttersprache)
  • Deutsch (Gut)
Reisebereitschaft
Europa
Arbeitserlaubnis
  • Europäische Union
  • Schweiz
Profilaufrufe
1128
Alter
34
Berufserfahrung
11 Jahre und 4 Monate (seit 11/2012)